Sky Factory T5 Fluorescent lighting is the standard option for Luminous SkyCeiling™ installations. T5 fluorescents are long lasting*, energy efficient and economical. The housing for Luminous SkyCeilings provides uniform illumination across the image. We use 6500K daylight balanced bulbs that provide a light that the eye and mind does not distinguish from real daylight, and significantly contributes to the illusion of nature that accomplishes our goal - triggering the psycho-physiological relaxation response.
* compared to other fluorescents
Technical Specifications
Uniform light distribution of our light housing allows even open blue sky to be rendered without hot spots or shadowing that diminishes the illusion.
Housing (light-box)
CNC formed code gauge cold rolled steel
5-stage pretreatment
Powder coated gloss white
750 HR salt spray test
Built in safety hanger wire attachment points
Designed for easy access to service electrical components/lamps
Wiring & Electrical:
All fixtures rated for UVI (universal input voltage) 120-277VAC, 50/60Hz code gauge TFN wire used throughout, rated for required temperatures 7/8" knockout for easy electrical connection
Ballasts:
Class P<10% THD (>0.99 PF)
Sound Rated A
Non-Dimmable
.29A @ 120v (34.8 watts).13A @ 277v (36 watts)
0-10v Dimmable
Dimmable from 1-100% through supplied low voltage 0-10v dimmer switch.28A @ 120v (33.6 watts)
.13A @ 277v (36 watts)
DALI Dimmable
Dimmable from 1-100% through supplied momentary contact switch or DALI control systemCompatible with Programmable Luminous SkyCeiling
.29A @ 120v (34.8 watts)
.13A @ 277v (36 watts)
Lamps
T5 fuorescentMost energy effcient in fluorescents
Lowest CO2 emissions (40% less than a TL-D lamp, 26% less than TLD 800)
Lowest mercury content in the fluorescent industry, 100% lead free
Product dimension only 16mm (5/8") diameter, 40% less compared to TLD lamps
Installation
Easily installed into standard 2'x2' 15/16" grid systems
Factory Installed Options
Seismic
Corrosion resistanct aluminum housing
Alternate ballast
Listings:
UL, CUL, and CE